« Table of Contents PDF (315Kb)

Community Eye Health J 2008;21(65): 4-5

SMALL INCISION CATARACT SURGERY

Small incision cataract surgery: tips for avoiding surgical complications

Reeta Gurung

Reeta Gurung
Deputy Medical Director, Tilganga Eye Centre, Kathmandu, Nepal. Email: reetagurung@gmail.com

Albrecht Hennig

Albrecht Hennig
Programme Director, Eastern Regional Eye Care Programme, Lahan, Nepal. Email: akhennig@gmx.net

Keywords: Small Incision Cataract Surgery; Cataract; Postoperative Complications; Prevention and Control 

Small incision cataract surgery (SICS) is one of the cataract surgical techniques commonly used in developing countries. This technique usually results in a good visual outcome and is useful for high-volume cataract surgery.1–3

This article describes how to minimise surgical complications in SICS.

Before you begin

With SICS, as with all cataract surgery techniques, it is mandatory to perform a thorough preoperative assessment of the patient (see article on page 12). This will allow the surgeon to prepare for anticipated complications – for example, a dislocated or subluxated lens – and to plan the operation accordingly.

Prepare the patient in the following way:

Other measures will also help to reduce the risk of postoperative endophthalmitis: proper hand washing (see ‘how to’ article on page 17), the use of sterile instruments, the ‘non-touch’ technique, the subconjunctival injection of antibiotics,4,5 and the intracameral injection of cefuroxime6 at the end of surgery (see article on page 11). The dose of intracameral cefuroxime must be meticulously prepared, as no commercially made preparation is available (see box on page 11).

Tunnel construction

Tunnel size

Tunnel size The expected size and density of the nucleus should determine the size of the tunnel. For example, the extraction of immature cataracts in younger patients may only require a small tunnel, just large enough for the intraocular lens (IOL) optic to pass through. Very big, brown nuclei require a larger tunnel size. These nuclei can sometimes be up to 8 mm in diameter and 4 mm thick. However, a large tunnel need not be a problem: even larger tunnels are self-sealing and don’t need suturing if they are prepared correctly. If there is doubt about the self-sealing effect, the surgeon may apply one or two sutures at the end of surgery. If correctly tied, these will, at the same time, reduce any induced astigmatism.

Constructing the tunnel

Opening of the anterior capsule

This can be done by different techniques (such as linear capsulotomy (Figure 5), the ‘can-opener’ technique, and triangular or V-shaped capsulotomy) or by capsulorhexis.

Capsulotomies are easy to perform, but may lead to uncontrolled capsular tear extension, posterior capsule rupture, vitreous loss, and IOL decentration. These problems can be avoided by a careful hydro-dissection, especially in patients with posterior polar cataract or posterior lenticonus (hydrodissection is most effective if the fluid is injected directly into the capsule7). Keeping instrument manipulation to a minimum during surgery will also help you to avoid posterior capsule rupture.

The best capsular opening is a continuous curvilinear capsulorhexis (CCC): it will guarantee a long-term, ‘in the bag’ IOL centration (Figure 6). However, CCC is more difficult to learn. This technique sometimes requires staining of the capsule and the opening also needs to be large enough for the nucleus to get through. It may therefore not be possible to use this technique in eyes with very big nuclei and smaller pupils. In such a situation, a linear, triangular, or other capsulotomy may be preferred.

Failing to complete the anterior capsulotomy, making a too-small CCC, and pulling residual anterior capsular tags can cause the posterior capsule to rupture. Early recognition and correction of these problems is very important to avoid further complications.

LINKS TO PICTURES

Opening of the anterior capsule

Nucleus removal

During SICS, different techniques can be used to remove the nucleus: either hydroexpression alone (using an anterior chamber maintainer), hydroexpression plus extraction (using an irrigating vectis or Simcoe cannula), or extraction alone (using a ‘fishhook’ needle). Problems with these different SICS techniques are mainly related to the size of the tunnel and the proximity of the nucleus to the corneal endothelium.

Difficulties with nucleus delivery are mostly due to the inner tunnel opening being too small. This should be checked before nucleus removal, e.g. with the visco cannula (Figure 7). If there is any doubt about the correct tunnel size, it is better to further enlarge the tunnel before removing the nucleus. However, the surgeon should avoid cutting into the anterior chamber’s angle while enlarging the inner tunnel opening, as this carries an increased risk of hyphaema.

While lifting the nucleus into the anterior chamber (Figure 8), special care is required in patients with pseudoexfoliation and in older patients with weak zonules.

While delivering the nucleus through the tunnel, accidental contact between the nucleus and the corneal endothelium must be avoided. Otherwise, postoperative corneal oedema, and sometimes even corneal decompensation, may occur.

In order to avoid such corneal problems, you must inject sufficient viscoelastic fluid between the lens and the cornea to protect the endothelium. Instruments for nucleus removal, such as the irrigating vectis, Simcoe cannula, or fishhook, should be kept away from the cornea and should not push the nucleus against the cornea during nucleus delivery.These instruments should push slightly posteriorly, which will help to open the incision for easier nucleus delivery (Figures 9 & 10). In addition, gently pulling the bridle suture makes nucleus delivery through the tunnel easier.

Removal of the cortex

Most of the lens cortex can be removed with a Simcoe cannula through the tunnel (Figure 11). A sub-incisional cortex can be safely aspirated through a side port at 130–180° from the incision site.8 If stripping of Descemet’s membrane occurs while cleaning the cortex, great care should be taken not to tear it off. If this happens, air should be injected into the chamber at the end of the operation to push Descemet’s membrane against the cornea.

While clearing the cortex with a Simcoe cannula, posterior capsule rupture and vitreous loss may occur. This can be avoided by carefully watching the posterior capsule. Wrinkles indicate that the posterior capsule is caught in the aspiration port of the Simcoe cannula. This requires immediate back-flushing to avoid posterior capsular rupture.

To reduce the risk of a postoperative increase in intraocular pressure, thorough removal of viscoelastics is required.

LINKS TO PICTURES

Removal of the cortex

References

1 Hennig A, Kumar J, Yorston D, Foster A. Sutureless cataract surgery with nucleus extraction: outcome of a prospective study in Nepal. Br J Ophthalmol 2003;87:266–270.

2 Hennig A et al. World Sight Day and cataract blindness. Br J Ophthalmol 2002;86:830–31.

3 Ruit SPG, Gurung R, Tabin G, Moran D, Brian G. An innovation in developing world cataract surgery. Clin Exp Ophthalmol 2000;28:274–279.

4 Ng JQ, Morlet N, Bulsara MK, JB Semmens. Reducing the risk for endophthalmitis after cataract surgery: population-based nested case-control study: endophthalmitis population study of western Australia sixth report. J Cataract Refract Surg 2007;33(2):269–80.

5 Kamalrajah S, Ling R, Silvestri G, Sharma NK, Cole MD, Cran G, RM Best. Presumed infectious endophthalmitis following cataract surgery in the UK: a case-control study of risk factors. Eye 2007;21(5):580–6.

6. ESCRS Endophthalmitis Study Group. Prophylaxis of postoperative endophthalmitis following cataract surgery: results of the ESCRS multicenter study and identification of risk factors. J Cataract Refract Surg 2007;33(6):978–88.

7 Schroeder B. Sutureless cataract extraction: complications and management; learning curves.. Comm Eye Health J 2003;16(48):58–60.

8 Traianidis P, Sakkias G, Avramides S. Prevention and management of posterior capsule rupture. Eur J Ophthalmol 1996;6(4):379–82.